You are using an outdated browser Internet Explorer. It does not support some functions of the site.

Recommend that you install one of the following browsers: Firefox, Opera or Chrome.

Contacts:

+7 961 270-60-01
ivdon3@bk.ru

Methods of measurement of small inductors for radio systems on a chip

Abstract

Methods of measurement of small inductors for radio systems on a chip

V.G. Sapogin, N.N. Prokopenko, A.S. Budyakov

Incoming article date: 13.03.2013

Technique for measurement of inductances (L) about 1 nanohenry or less one, is discussed. Two measurements of inductance L are executed. First one is executed for stub length l0, another - for stub length, shortened into N times. Formula for calculation of unknown inductance’ error has been obtained, where determination of unknown L with error closed to meter error has been succeeded by choice of parameters. It is shown that required measurement’s error of initial stub length for N=2 and N=5 is in tens micrometers’ range. Techniques for error’s diminishing have been considered. Estimation for basic stub length of 6,6 mm and 8,3 mm for N=2 and N=5 respectively has been executed. 

Keywords: inductance, least-squares procedure, meter error, stub base